Note: This is an obsolete section of the FreeRTOS website. If you want to view these pages but cannot see the menu frame then click here. Otherwise click here to visit the main FreeRTOS website. |
Time measurements were obtained using an oscilloscope attached to a digital output. See the "Tests Performed" section for more details.
Results for the AVR using the IAR compiler.
Test Result 16bit addition 55.2μs 16bit multiplication 71.4μs 16bit division 536μs 32bit multiplication 180μs 32bit subtraction 88.1μs Bubble sort 834μs Block memory move and compare 7.9ms Conditional branch to procedure 245.6μs PUSH’ing and POP’ing 258μs, (258μs)